Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JACC Cardiovasc Interv ; 7(11): 1237-44, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25326744

RESUMO

OBJECTIVES: The aim of this study was to identify predictors of occlusion intolerance (OI) developing during proximal protected carotid artery stenting (CAS). BACKGROUND: The use of proximal embolic protection devices, such as endovascular occlusion, during CAS has been demonstrated to be particularly safe and effective. However, endovascular occlusion can expose the ipsilateral hemisphere to hypoperfusion and produce transient neurological symptoms (OI). METHODS: From March 2010 to March 2012, 605 consecutive patients underwent proximal protected CAS at our institution. To identify independent predictors of OI, a multivariate logistic regression model was developed that included all patients' clinical/angiographic and procedural characteristics. RESULTS: OI developed in a total of 184 patients (30.4%). Compared with patients in whom OI did not develop, those who experienced OI had lower occlusion pressure (OP) (42.3 ± 12.7 mm Hg vs. 61.9 ± 15.4 mm Hg, p < 0.001). Receiver-operating characteristic curve analysis demonstrated that OP was the most consistent predictor of OI with a C-statistic of 0.85 (95% confidence interval [CI]: 0.82 to 0.88) with best cutoff being ≤40 mm Hg (sensitivity, 68.5%; specificity, 93.3%). By logistic regression analysis, the most powerful independent predictor of OI developing was an OP ≤40 mm Hg (odds ratio: 33.2, 95% CI: 19.1 to 57.7) and the most powerful clinical predictor of such OP was the presence of contralateral internal carotid artery occlusion (odds ratio: 3.1, 95% CI: 1.5 to 6.2). CONCLUSIONS: OI may occur in as many as one-third of the patients undergoing proximal protected CAS. This event is more common in those patients with an OP ≤40 mm Hg. Patients presenting with concomitant occlusion of the contralateral internal carotid artery more frequently have an OP ≤40 mm Hg.


Assuntos
Angioplastia , Artéria Carótida Interna/fisiopatologia , Estenose das Carótidas/terapia , Circulação Cerebrovascular , Transtornos Cerebrovasculares/etiologia , Dispositivos de Proteção Embólica , Stents , Idoso , Angioplastia/efeitos adversos , Angioplastia/instrumentação , Área Sob a Curva , Estenose das Carótidas/diagnóstico , Estenose das Carótidas/fisiopatologia , Transtornos Cerebrovasculares/diagnóstico , Transtornos Cerebrovasculares/fisiopatologia , Distribuição de Qui-Quadrado , Feminino , Humanos , Itália , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Valor Preditivo dos Testes , Curva ROC , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
2.
J Am Coll Cardiol ; 55(16): 1661-7, 2010 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-20394868

RESUMO

OBJECTIVES: This single-center registry presents the results of proximal endovascular occlusion (PEO) use in an unselected patient population. BACKGROUND: In published multicenter registries, the use of PEO for carotid artery stenting (CAS) has been demonstrated to be safe and efficient in patient populations selected for anatomical and/or clinical conditions. METHODS: From July 2004 to May 2009, 1,300 patients underwent CAS using PEO. Patients received an independent neurological assessment before the procedure and 1 h, 24 h, and 30 days after the procedure. RESULTS: Procedural success was achieved in 99.7% of patients. In hospital, major adverse cardiac or cerebrovascular events included 5 deaths (0.38%), 6 major strokes (0.46%), 5 minor strokes (0.38%), and no acute myocardial infarction. At 30 days of follow-up, 2 additional patients died (0.15%), and 1 patient had a minor stroke (0.07%). The 30-day stroke and death incidence was 1.38% (n = 19). Symptomatic patients presented a higher 30-day stroke and death incidence when compared with asymptomatic patients (3.04% vs. 0.82%; p < 0.05). No significant difference in 30-day stroke and death rate was observed between patients at high (1.88%; n = 12) and average surgical risk (1.07; n = 7) (p = NS). Operator experience, symptomatic status, and hypertension were found to be independent predictors of adverse events. CONCLUSIONS: The use of PEO for CAS is safe and effective in an unselected patient population. Anatomical and/or clinical conditions of high surgical risk were not associated with an increased rate of adverse events.


Assuntos
Oclusão com Balão/métodos , Artéria Carótida Interna , Estenose das Carótidas/terapia , Cuidados Pré-Operatórios/métodos , Sistema de Registros , Stents , Idoso , Feminino , Seguimentos , Humanos , Incidência , Embolia Intracraniana/epidemiologia , Embolia Intracraniana/prevenção & controle , Masculino , Seleção de Pacientes , Estudos Prospectivos , Fatores de Risco , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...